Homepage / Copper cabling / Copper cables / Indoor / Unshielded / Category 6A / securityNET U/UTP Category 6A LSZH Cca cable 500m

securityNET U/UTP Category 6A LSZH Cca cable 500m

The securityNET Category 6A U/UTP installation twisted-pair cable is a four-pair data transmission cable designed for indoor telecommunications and structured cabling installations. It is intended for connecting network devices such as computers, routers, switches, and IP CCTV cameras.
Solid copper conductors ensure stable data transmission and compliance with Category 6A requirements, including Power over Ethernet (PoE) applications. The cable is commonly used in LAN networks and IP surveillance systems in environments not exposed to significant electromagnetic interference.
The cable complies with the requirements of the ISO/IEC 11801, EN 50173, and EIA/TIA 568-C.2 standards.

Product specifications

Detailed product specifications

Application

Indoor

Cables designed for indoor installations are engineered to operate in stable environmental conditions typical of residential, office, and infrastructure buildings. Their construction, based on conductors made of 100% pure solid copper, ensures stable and consistent transmission performance along the entire cable length. The use of solid copper minimizes signal loss and supports compliance with the requirements of ICT systems. These cables are fully compatible with solutions used in structured cabling systems.

Category

6A (class EA)

Category 6A, corresponding to Class EA, is a structured cabling standard designed for data transmission speeds of up to 10 Gb/s (10GBASE-T). According to the standard, it operates at frequencies of up to 500 MHz, ensuring a high margin of transmission performance and stable operation in modern high-bandwidth networks.

Category 6A cabling is widely used in LAN networks, data centers, and IP surveillance systems, enabling reliable connections between devices such as switches, routers, servers, and IP cameras. In accordance with structured cabling standards, the maximum permanent link length should not exceed 90 meters, assuming the use of patch cords up to 5 meters long on both ends of the channel.

Shielding

U/UTP

U/UTP twisted pair is an unshielded cable, both at the overall cable level and for individual wire pairs. Crosstalk and interference reduction rely on precisely engineered pair twisting in accordance with structured cabling standards. The cable design includes a central plastic cross separator, which separates individual wire pairs and helps reduce pair-to-pair crosstalk.

Due to the lack of protection against electromagnetic interference, U/UTP cable requires proper installation route planning. Appropriate separation should be maintained from power cables, other signal paths, and devices generating electromagnetic fields. This cable is intended for installations in low-EMI environments, such as standard office and residential spaces, where proper cable organization is essential.

Sheath

LSZH

The LSZH (Low Smoke Zero Halogen) sheath used in twisted pair cables is designed to provide enhanced fire safety. This material contains no halogens and, when exposed to high temperatures, emits minimal smoke without producing aggressive corrosive gases.

LSZH-sheathed cables are intended for indoor installations in environments with elevated safety requirements, such as public buildings, offices, data centers, and evacuation routes. Compared to PVC, the sheath is generally less flexible, but it provides better protection for people, infrastructure, and equipment in emergency situations.

CPR class

Cca

Cca-class cables demonstrate limited contribution to fire development. This classification is based on test results in accordance with EN 50399 and EN 60332-1-2 standards, including the measurement of heat release, fire growth rate, and flame spread.

The full class designation includes additional parameters: smoke production (s1, s2, s3), flaming droplets (d0, d1, d2), and the acidity of combustion gases (a1, a2, a3). Cca cables are subject to the AVCP 1+ assessment system, which includes production facility certification and periodic control testing.

Cables of this class are used in facilities with elevated fire safety requirements, such as office buildings, hotels, schools, evacuation routes, and common areas of multi-family residential buildings. In many EU countries, the Cca class is the standard required for installations in public-use buildings.

PoE

IEEE 802.3bt (PoE++)

The PoE++ Type 4 standard, compliant with IEEE 802.3bt, enables power delivery to network devices with up to 90 W while simultaneously transmitting data. Power is supplied using all four wire pairs (4PPoE), allowing support for high-power devices without additional power sources. The maximum transmission channel length is up to 100 meters.

PoE++ Type 4 is used to power advanced Wi-Fi access points, high-power CCTV cameras including PTZ and heated models, access control systems, information kiosks, multimedia terminals, Video VoIP devices, and other active equipment requiring approximately 71–90 W of power, depending on the power class.

Color

Orange (RAL 2004)

A color used in higher-category cabling where rapid identification of transmission paths is essential. Its vivid appearance makes it easier to distinguish cables in routes and telecommunications cabinets, reducing the risk of service errors. It is ideal for professional installations, data centers, and high-density cabling environments.

Warranty

5 years

By choosing securityNET cables, you are investing in solutions designed for long-term and reliable performance in network installations. These products are covered by a 5-year manufacturer’s warranty, confirming the quality of the materials used and the control of the production process.
The warranty covers manufacturing defects and workmanship faults revealed during use in accordance with the intended application and applicable installation standards.

 

Packaging

500m drum

Cable supplied on a standard 500 m reel. This packaging format is intended for larger installations, enabling efficient deployment of longer cable runs.

Technical specifications

ParameterValue
Outer diameter 6,4mm
Kategory/Class 6A (Ea class)
Shielding U/UTP
Copper conductor thickness/AWG AWG23
Conductors solid wire
Conductor material copper
Conductor insulation HDPE 1,02mm
Sheath thickness 0,55mm
Outer sheath LSZH
CPR class Cca
Cable construction 4x2
Bending radius during installation 52mm
ParameterValue
Impedance 100Ω
Delay Skew ≤45
Nominal propagation velocity (NVP) 69%
Linear resistance (max) 9,5 (Ω/100m)
Sparator yes
Operating temperature from -20°C to 70°C
Installation temperature from -5°C to 60°C
Quantity per package 500m
Insulation color RAL 2004
RoHS yes

Downloads