Homepage / Copper cabling / Copper cables / Outdoor / Shielded / Category 6 / securityNET F/UTP category 6 PE outdoor dry cable 500m

securityNET F/UTP category 6 PE outdoor dry cable 500m

The securityNET Category 6 F/UTP installation twisted-pair cable is a four-pair data transmission cable designed for outdoor telecommunications and structured cabling installations. It is intended for connecting network devices such as computers, routers, switches, and IP CCTV cameras.
The foil shield helps reduce the impact of electromagnetic interference, while solid copper conductors ensure stable data transmission and compliance with Category 6 requirements, including Power over Ethernet (PoE) applications. The cable is commonly used in outdoor LAN networks and IP surveillance systems.
The cable complies with the requirements of the ISO/IEC 11801, EN 50173, and EIA/TIA 568-C.2 standards.

Product specifications

Detailed product specifications

Application

Outdoor, dry

Cables designed for outdoor dry-environment applications are engineered for use outside buildings in locations not exposed to direct moisture. The use of conductors made from 100% pure solid copper, combined with appropriate cable construction, ensures stable transmission performance and mechanical durability. This solution helps maintain electrical properties under varying temperature conditions and mechanical stress. These cables are well suited for routing along building facades, in cable trays, and within protective installation conduits.

Category

6 (class E)

Category 6, corresponding to Class E, is a structured cabling standard designed for data transmission speeds of up to 1 Gb/s (1000BASE-T). According to the standard, it operates at frequencies up to 250 MHz, ensuring stable data transmission and an appropriate performance margin for network installations. Category 6 can also support higher data transmission speeds of up to 10 Gb/s; however, this speed is only achievable over shorter distances, typically ranging from 37 to 55 meters.

Category 6 cabling is widely used in LAN, WAN, and IP surveillance systems, enabling connections between devices such as switches, routers, servers, and IP cameras. In accordance with structured cabling principles, the maximum permanent link length should not exceed 90 meters, assuming the use of patch cords up to 5 meters long on both ends of the transmission channel.

Shielding

F/UTP

F/UTP twisted pair cable features an overall foil shield surrounding all wire pairs, without individual shielding for each pair. This design reduces the impact of external electromagnetic interference and minimizes cable-generated interference affecting the surrounding environment.

This cable is intended for installations in environments with moderate levels of EMI, where U/UTP may not provide sufficient transmission stability. It requires proper grounding of the shield along the entire transmission path. It is recommended for routing near electrical installations and within denser cable bundles. It performs well in installations with high requirements for transmission stability and performance.

Sheath

PE

The PE (polyethylene) jacket used in twisted pair cables is primarily intended for outdoor installations. This material offers excellent resistance to moisture, UV radiation, and varying weather conditions, allowing for long-term cable operation outside buildings.

Cables with a PE jacket are stiffer than their PVC or LSZH counterparts; however, they provide superior mechanical and environmental resistance. Due to their flammable properties and lack of low-smoke characteristics, they are not intended for indoor building installations.

CPR class

Fca

Euroclass Fca is the lowest fire reaction classification level in the CPR system. Cables in this class do not have confirmed performance parameters regarding flame spread, heat release, or smoke production.

Cables classified as Fca are not approved for permanent building installations covered by CPR regulations. Their use is limited to temporary, outdoor, or other installations that are not subject to building fire safety requirements.

In projects subject to CPR requirements, the use of cables with at least Eca classification is mandatory. The selection of the appropriate Euroclass should be based on project documentation and local fire safety regulations.

PoE

IEEE 802.3bt (PoE++)

An installation based on the PoE++ standard (IEEE 802.3bt, Type 3) enables simultaneous data transmission and power delivery to end devices using all four wire pairs (4PPoE), with a maximum power output of up to 60 W per port. This solution allows network devices to be powered without the need for a local power source. The maximum transmission channel length is up to 100 meters. A higher cable category provides lower power loss and better operating conditions at elevated temperatures, especially in cable bundles and telecommunications cabinets.

The PoE++ standard is used to power a wide range of active devices, including VoIP phones, Wi-Fi access points (802.11n and 802.11ac), CCTV cameras, including PTZ and heated models, access control systems, alarm devices, video terminals, and information kiosks. This solution is designed for devices with power requirements of up to approximately 51 W while maintaining stable operation across the entire infrastructure.

Color

Czarny (RAL 9005)

A color primarily used in technical and outdoor installations. In the case of PE jackets, it provides enhanced UV resistance due to the carbon black content, which reduces material aging during prolonged exposure to sunlight.

Warranty

5 years

By choosing securityNET cables, you are investing in solutions designed for long-term and reliable performance in network installations. These products are covered by a 5-year manufacturer’s warranty, confirming the quality of the materials used and the control of the production process.
The warranty covers manufacturing defects and workmanship faults revealed during use in accordance with the intended application and applicable installation standards.

 

Packaging

500m drum

Cable supplied on a standard 500 m reel. This packaging format is intended for larger installations, enabling efficient deployment of longer cable runs.

Technical specifications

ParameterValue
Outer diameter7,4mm
Kategory/Class6 (class E)
ShieldingF/UTP
Copper conductor thickness/AWGAWG23
Conductorssolid wire
Conductor material100% copper
Conductor insulationPE 1,10mm
Sheath thickness0,6mm
Outer sheathPE
CPR classFca
Cable construction4x2
Bending radius during installation60mm
ParameterValue
Impedance100Ω
Delay Skew≤45
Nominal propagation velocity (NVP)68%
Linear resistance (max)9,5 (Ω/100m)
Sparatoryes
Operating temperaturefrom -30°C to 60°C
Installation temperaturefrom -5°C to 70°C
Quantity per package500m
Insulation colorRAL 9005
RoHSyes

Downloads