Homepage / Copper cabling / Copper cables / Outdoor / Shielded / Category 5e / securityNET F/UTP category 5e PE outdoor dry cable 500m

securityNET F/UTP category 5e PE outdoor dry cable 500m

securityNET installation twisted-pair cable is designed for connections between multimedia signal distribution points and user connection sockets. The F/UTP (shielded) twisted-pair cable is suitable for installation in computer networks, telephone networks, CCTV systems, etc., which are exposed to electromagnetic 1 interference. It has a PE outer jacket that protects it from damage resulting from external conditions. The cable meets the requirements of structured cabling standards: ISO/IEC 11801, EN 50173, EIA/TIA 568-C.2.

securityNET F/UTP category 5e PE outdoor dry cable 500m

A dependable network you can trust

The securityNET twisted pair cable is made of the highest quality copper, making it the optimal choice for building connections designed to last for years. It has undergone rigorous strength tests over a 90-meter length using a Fluke Networks DSX-8000 meter. Therefore, if you are seeking materials with exceptional durability, this is an excellent option.

securityNET F/UTP category 5e PE outdoor dry cable 500m

Polyethylene jacket for outdoor installation

Engineered for outdoor environments, the PE jacket protects cables from harsh conditions such as UV rays, extreme temperatures, and high humidity. securityNET cables, with their robust black jacket, offer superior mechanical protection compared to standard cables. The fill-less design makes them ideal for above-ground installations.

Technical specifications

Outer diameter

Outer diameter

6,3mm
Category/class

Category/class

5e (class D)
Shielding

Shielding

F/UTP
Copper conductor thickness/AWG

Copper conductor thickness/AWG

0,51mm/AWG24
Wires

Wires

solid wire
Conductors

Conductors

100% copper
Conductor insulation

Conductor insulation

HDPE, conductor diameter 1.02mm
Coating thickness

Coating thickness

0,55mm
Outer sheath

Outer sheath

LDPE
CPR class

CPR class

Fca
Cable construction

Cable construction

4x2
Bend radius at installation

Bend radius at installation

51mm
Impedance

Impedance

100Ω
Delay Skew

Delay Skew

≤45
Nominal propagation velocity (NVP)

Nominal propagation velocity (NVP)

68%
Linear Resistance (max.)

Linear Resistance (max.)

9,5 (Ω/100m)
Pair separator

Pair separator

not
Operating temperature

Operating temperature

from -30°C to 60°C
Installation temperature

Installation temperature

from -10°C to 70°C
Quantity per package

Quantity per package

500m
Insulation color

Insulation color

RAL 9005
RoHS

RoHS

yes

Downloads

Key Elements for Ethernet Network

Brochures

Key Elements for Ethernet Network

Download file
SecurityNET 2022 cable catalog

Marketing materials

SecurityNET 2022 cable catalog

Download file
SecurityNET logo

SecurityNET logo

Download file